Home Company Products Authentic Support Contact Us
¡@
5RK60GU-AF
AC Motor/ Fixed Speed Motor/ Reversible Motors/ 60W/ 5RK60GU-AF
Series¡G K Series
Motor Gear Box Fan(Option)
5RK60GU-AF 5GU3K FF

¡¯ Motor 5RK60GU-AF
¡¯ Gear Box 5GU3K

Gear Type¡G
Parallel Shaft(5GU¡¼TK) ¡³
Parallel Shaft(5GU¡¼K) ¡´
Right-Angle:Solid Shaft(5GU¡¼RA) ¡³
Right-Angle:Hollow Shaft(5GU¡¼RH) ¡³
Linear Horizontal motiont(5LB¡¼-¡¼) ¡³
Linear Vertical-line motiont(5LF¡¼-¡¼) ¡³
Gear Ratio Selection¡G  
Option : P
¡@ ¡@
P:
¡@
Contains a built-in thermal protector. When a motor overheats for any reason, the thermal protector is opened and the motor stops, and the power supply to the electromagnetic brake is kept and the brake is released. When the motor temperature drops, the thermal protector closes and the motor restarts. Be sure to turn the motor off before inspecting.
¡@ ¡@
:: Motor Specifications
Frame Size Wiring Type Output Power Voltage Frequency Current Starting Torque Rated Torque Rated Speed Capacitor
[mm] [W] [V] [Hz] [A] [Kgfcm]  [Kgfcm]  [r/min] [£gF]
90 Lead wire 60 Single-phase
100
50 1.4 3.2 4.5 1300 15
90 Lead wire 60 Single-phase
110
60 1.4 3 3.8 1650 15
The listed rated torque and starting torque of the reversible motors do not consider the application of any brake.

¡@

 

:: Gear Box Specifications
Gear Type Gear Ratio Direction of Rotation Frequency Speed Permissible Torque Permissible Overhung Load Permissible Thrust Load
from the tip of the shaft 10mm from the tip of the shaft 20mm
  ¡@ ¡@ [Hz] [r/min] [Kgfcm] [Kgfcm] [Kgfcm] [Kgfcm]
Parallel Shaft 3 Same direction as the motor shaft 50 500 10.93 40 50 15
Parallel Shaft 3 Same direction as the motor shaft 60 600 9.23 40 50 15
¡´
¡@
The speed is calculated by dividing the motor's synchronous speed (50 Hz: 1500 r/min, 60 Hz: 1800 r/min) by the gear ratio. The actual speed is 2 to 20% less than the displayed value, depending on the size of the load.
¡´
The actual speed is 2 to 20% less than the displayed value, depending on the size of the load.
:: Characteristics/Dimensions/Wiring Diagrams
Characteristics/Wiring Diagrams 2IK6A-A.cad
Dimensions 2IK6A-A.cad

:: Motor General Specifications
Insulation Resistance 100M ohms or more when measured by a 500 VDC megger between the windings and the frame after rated motor operation under normal ambient temperature and humidity.
Dielectric Strength Sufficient to withstand 1.5 kV at 50 Hz and 60 Hz applied between the windings and the frame for 1minute after rated motor operation under normal ambient temperature and humidity.
Temperature Rise 144¢XF (80¢XC) or less in the coil, as measured by the resistance change method after rated operation with a gearhead installed.
Insulation Class Class F (302¢XF [150¢XC])
Overheat Protection Built-in thermal protector (automatic return type) Open: 266¢XF ¡Ó 9¢XF (130¢XC ¡Ó 5¢XC) Close: 179.6¢XF ¡Ó 27¢XF (82¢XC ¡Ó 15¢XC)
Ambient Temperature 14¢XF ~ 104¢XF (-10¢XC ~ +40¢XC) (nonfreezing)
Ambient Humidity 85% maximum (noncondensing)

:: Accessories (included)
Model Quantity Product/Description/Standards PDF
Capacitor 1 For single-phase Motor CAD
Screw 4 Screw CAD
Key 4 Key CAD
Leading Wire 1 length 20cm CAD
Motor with Fan 1 link the Motor shaft ¡Afor over 60W Motor  CAD
Sheath of Shaft 1 Fpr  protect external shaft   CAD
¡@ ¡@ ¡@ ¡@

:: Accessories (sold separately)

Model

Product/Description/Standards PDF
Mounting Brackets Motor/GearBox Mounting Brackets/For Frame Size have 60mm¡B80mm¡B90mm¡B104mm  Material:stainless steel CAD
Leading Wire length 30cm CAD
Leading Wire length 50cm CAD
Leading Wire length 100cm CAD
Independent Fan Motor with Independent Fan¡Afor over 60W Motor  CAD
Thermal protector switch Contain a built-in thermal protector. If a motor overheats for any reason, the thermal protector is opened and the motor stops. When the motor temperature drops, the thermal protector closes and the motor restarts. Be sure to turn the motor off before inspecting.

CAD

¡@ ¡@ ¡@

Copyright ©2005 SYMOTOR SEIKO(SHANG YANG) LTD.. All right reserved.